| ■TOP |
 |
■Products Guide
|
|
Extraction Robots with AC servo drive in Traverse Axis!!
|

|
|
For 50-250 ton Molding Machine Application |
|
■Introduce product and functions
3or5 axis Pneumatic Extraction Robots with AC servo motor in traverse axis.
Combining High Performance of AC servo Technology and High Price Performance
of Pneumatic Operation.
|
|
● |
High performance mechanism
Linear guides on all axis keep accuracy and durability. |
|
● |
Various functions in standard specification
Palletizing on traverse axis, sampling mode,
initial rejection, NG rejection....... lots more! |
|
● |
Simple structure makes high productivity
Accurate and durable take-out
.....continuous operation. |
|
● |
Operational Touch Pendant
Compact and light, Easy to operate by a hand,
Multiple languages are available. |
|
 |
| Power Supply |
AC200V±10% 50/60Hz |
| Max electric power required |
1kVA |
| Normal air pressure |
0.5〜0.6MPa |
| Max air pressure capacity |
0.97MPa |
| Max loading capacity |
7kgs(including chuck unit) |
| Air Consumption |
Single Arm: 45Nl/cyc, Double Arms: 65Nl/cyc |
| Model |
Arm |
For Molding Machine
Application |
Movable Range |
Traverse
Stroke
max [mm] |
Vertical Stroke
max [mm] |
Horizontal Stroke
max [mm] |
|
Parts-side |
Runner-side |
Parts-side |
Runner-side |
| RZ-200C |
S |
50〜250ton |
1400 |
800 |
150 |
| W |
800 |
850 |
150 |
100 |
| S:Single Arm |
W:Double Arms |
| Standard Specifications |
| 1 |
Parts Vacuum Circuit w/part detection |
| 2 |
Mechanical Parts Chuck w/part detection |
| 3 |
Parts Side Runner Chuck Circuit (including Runner detection) |
| 4 |
A-Type Wrist Turn Unit |
| 5 |
Horizontal Wrist Turn Unit |
| 6 |
Runner release Positioning |
| 7 |
Traverse Axis Palletizing of 225 positions |
| 8 |
Intermediate Traverse Wait Positioning |
| 9 |
Definable Auxiliary Machine Interlock |
| 10 |
Periodical Sampling Mode |
| 11 |
Priority Sampling Mode |
| 12 |
Release between Molds |
| 13 |
Initial Reject Mode |
| 14 |
NG Parts Reject Mode |
| 15 |
Mold Memory with comments (numeric, alphabets) 15 molds |
| 16 |
Maintenance Monitor |
| 17 |
Operation Monitor (Operation Guide) |
| 18 |
Alarm Monitor (Alarm Report, Trouble Shooting) |
| 19 |
Overflow Reject Mode |
| 20 |
Molding Shutdown Mode after Consecutive NG Signals |
| Optional Specifications |
| 1 |
Parts Vacuum Dual-System Circuit (for increased volume of products) |
| 2 |
Parts Vacuum Dual-System Circuit (for Parts release 2 positions) |
| 3 |
Gate-Cut at Traverse End |
| 4 |
Inside Chuck Gate-Cut |
|
|